← Knowledge Hub

Fire Safety

Fire Door Checks: What Should You Look For?

Routine fire door checks help identify damage and faults that could reduce a door’s ability to resist fire and smoke. They are part of maintaining fire precautions, alongside competent assessment and suitable repairs.

A quick visual check does not certify a door’s fire performance. It can reveal problems that need action, but judging the specification, installation or suitability of an unknown doorset may require specialist inspection.

Start with the doors identified in your fire arrangements

Use the fire risk assessment and available door information to identify which doors perform a fire protection role. Give each door a location or reference that makes it easy to find again.

A check sheet is most useful when it follows the door through to resolution. Record the date, what was checked, any defect, the person responsible for action and the outcome. “Door on first floor damaged” may not be precise enough in a building with several similar doors.

Use a person who understands the checks and knows when to seek further advice. If the building has no reliable door information, flag that gap for competent review.

Check the leaf and frame

Look for visible damage, distortion, holes or alterations to the door leaf and frame. Pay attention to areas around handles, hinges, glazing and closers. A door that has been modified to fit new access equipment may need more than a routine maintenance check.

Check that the frame appears secure and that any glazing and associated components are intact. Do not assume that a replacement panel, letter plate or piece of hardware is suitable merely because it fits the opening.

Record concerns so the person inspecting or repairing the door can understand exactly what was observed.

Check closing and movement

Where the door is designed to self-close, check that it closes properly into its frame from appropriate opening positions, without catching on the floor or requiring a push. Where a latch is part of the intended arrangement, the door should engage as designed. [24]

Look for wedges, furniture, floor coverings or other obstructions. If the closer has been disconnected because the door is inconvenient, understand the reason and arrange a suitable solution. Do not disable a fire precaution to make daily access easier.

Doors held open by approved devices need arrangements appropriate to their system. A visual check alone is not a functional test of the entire alarm-linked release arrangement.

Look at seals and gaps carefully

Check for damaged, missing or painted-over seals where they form part of the intended doorset. Look for uneven or excessive gaps, but compare them with the door’s specification and competent guidance rather than applying one universal measurement to every edge and every door type. [24]

Timber, steel, glazed and specialist doors can have different requirements. The threshold detail may also differ from the head and jambs. A coin used as an informal gauge is not evidence that the whole doorset is suitable.

If the required specification cannot be established, obtain competent advice. Avoid fitting additional seals, planing edges or changing hardware without checking compatibility.

How often should checks take place

For business premises, set inspection and maintenance arrangements according to the fire risk assessment, use, condition and relevant system information. Heavily used doors or doors exposed to damage may need more frequent attention. [25]

A separate rule applies to certain multi-occupied residential buildings in England above 11 metres: communal fire doors must be checked at least every three months, and best endeavours must be used to check flat entrance fire doors at least every twelve months. These intervals are not a universal legal schedule for every UK workplace. [23]

Scotland, Wales and Northern Ireland have their own applicable arrangements; the Fire Safety (England) Regulations should not be presented as UK-wide law.

Act on defects and verify repairs

Prioritise defects according to their effect on the fire precautions. If a door protecting an escape route will not close, seek prompt competent advice on the risk and any immediate measures needed.

Use suitable people and compatible components for repairs. Keep the repair record and check the door works properly afterwards. Repeated faults may indicate a wider issue with installation, use or the chosen hardware.

FAQs

Does every workplace need quarterly fire door checks

No universal quarterly requirement applies to all workplaces. The specific residential rule in England has a defined scope. Other premises need a suitable assessment-led maintenance programme.

Can we repair a damaged door ourselves

Only where the person doing the work is competent and the repair is appropriate to the doorset. Unchecked modifications can affect performance.

Does a fire risk assessment replace specialist door inspection

Not necessarily. The assessment may identify where further inspection is needed. Agree the scope so the two activities are not confused.

How Secure Safety Solutions can help

If you are unsure what your doors or maintenance records are telling you, we can consider the concerns within your fire risk assessment arrangements and identify where specialist investigation is needed.

Discuss your fire safety concerns

Sources and further reading

General guidance. The arrangements you need depend on your activities, premises and location.